| Parameter | Nilai |
|---|---|
| Langkah | 2.5 mm |
| Keputusan | Approved Test |
| Amplitud | 0.35 mm (10 Hz ... 60.1 Hz) |
| Lebar [l] | 16.4 mm |
| kekerapan | 10 - 150 - 10 Hz |
| Tinggi [t] | 14.8 mm |
| Panjang [l] | 20 mm |
| Jenis Kejutan | Semi-sinusoid |
| Panjang Kupas | 3 mm |
| Kitaran Palam | 25 |
| Kelajuan sapuan | 1 octave/min |
| Pecutan | 30g |
| Barisan Produk | CONNEXIS Connectors XS |
| Jenis Produk | Printed Circuit Board Connector |
| Sistem penguncian | Lace lock |
| Bilangan baris | 2 |
| Keluarga Produk | DD21PC 0.85/ |
| Tekanan haba | 105 °C/168 h |
| Flange pengapit | Lace Flange |
| Warna (Perumahan) | Black (9005) |
| Jenis sambungan | Crimp connection |
| Nota tentang hubungan | These are connectors without switching capability (COC) according to DIN EN 61984. In the event of use as prescribed, they must not be plugged in or unplugged under voltage or load. |
| Bilangan tiang | 12 |
| Arahan Ujian | X, Y, and Z axes (pos. and neg.) |
| Skim Dimensi | |
| Bilangan kitaran | 25 |
| Keletihan kakisan | 0.2 dm3UNDER2in 300 dm3/40 °C/1 cycle |
| Jenis pembungkusan | Boxed Packaging |
| Rintangan sentuhan | 2.6 mΩ |
| Arus Nominal IN | 5 A |
| Voltan nominal UN | 160 V |
| Spesifikasi Ujian | DIN EN 60068-2-70:1996-07 |
| Voltan AC yang boleh ditanggung | 1.39 kV |
| Tahap pencemaran | 3 |
| Bahan penebat | PBT |
| Seksyen Konduktor AWG | 28 ... 18 |
| Rintangan Sentuh R1 | 2.6 mΩ |
| Rintangan Sentuh R2 | 2.6 mΩ |
| Tempoh kemalangan | 11 ms |
| Daya pasang masuk lebih kurang. | 6 N |
| Voltan nominal (II/2) | 200 V |
| Bilangan tiang yang diuji | 20 |
| Voltan saiz (III/3) | 40 V |
| Tempoh ujian setiap paksi | 2.5 h |
| Kumpulan bahan penebat | Ii |
| CTI mengikut IEC 60112 | 400 ≤ CTI |
| Voltan dimensi (III/2) | 160 V |
| Suhu Ambien (Perkhidmatan) | -55 °C ... 105 °C (depending on the rating curve) |
| Suhu Ambien (Pemasangan) | -5 °C ... 100 °C |
| Pemacu/PCB Arah Sambungan | 0 ° |
| Voltan sementara nominal (II/2) | 2.5 kV |
| Voltan Penebat Saiz (II/2) | 200 V |
| Voltan sementara nominal (III/2) | 2.5 kV |
| Voltan sementara nominal (III/3) | 2.5 kV |
| Voltan Penebat Saiz (III/2) | 160 V |
| Voltan Penebat Saiz (III/3) | 40 V |
| Nilai garisan rayapan minimum (II/2) | 1.5 mm |
| Voltan kejutan yang boleh ditanggung di paras laut | 2.95 kV |
| Nilai garisan rayapan minimum (III/2) | 1.5 mm |
| Nilai garisan rayapan minimum (III/3) | 1.6 mm |
| Tiang Bersebelahan Rintangan Penebat | > 5 MΩ |
| Voltan sementara dimensi (II/2) | 2.5 kV |
| Kelas mudah terbakar mengikut UL 94 | V0 |
| Kuasa apabila dicabut melalui tiang lebih kurang. | 6 N |
| Voltan Sementara Pendimensian (III/2) | 2.5 kV |
| Voltan sementara dimensi (III/3) | 2.5 kV |
| Suhu Ambien (Penyimpanan/Pengangkutan) | -40 °C ... 70 °C |
| Kelembapan relatif udara (penyimpanan/pengangkutan) | 30 % ... 70 % |
| Rintangan terhadap arus bocor (DIN EN 60112 (VDE 0303-11)) | CTI ≥400 to <600 |
| Nilai Minimum Jarak Penebat Udara - Medan Tidak Homogen (II/2) | 1.5 mm |
| Nilai Minimum Jarak Penebat Udara - Medan Tidak Homogen (III/2) | 1.5 mm |
| nilai minimum jarak penebat udara - medan bukan homogen (III/3) | 1.5 mm |
| Bahagian Konduktor/Jenis Konduktor/Daya Tegangan Nilai Nominal/Nilai Sebenar | AWG 28 / flexible / > 11 N |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi