| Parameter | Nilai |
|---|---|
| -10 °C ... 70 °C (flexible installation) | |
| merah | D-SUB25 (8) = () |
| Nota | The wires are marked and fitted with ferrules. The braided shield is routed to a separate cable end. |
| biru | D-SUB25 (7) = () |
| kelabu | D-SUB25 (5) = () |
| merah jambu | D-SUB25 (6) = () |
| Padang | 2.77 mm |
| hitam | D-SUB25 (9) = () |
| coklat | D-SUB25 (2) = () |
| hijau | D-SUB25 (3) = () |
| putih | D-SUB25 (1) = () |
| ungu | D-SUB25 (10) = () |
| kuning | D-SUB25 (4) = () |
| Ketinggian | ≤ 2000 m |
| Dilindungi | yes |
| merah-biru | D-SUB25 (12) = () |
| coklat-merah | D-SUB25 (24) = () |
| kelabu-merah jambu | D-SUB25 (11) = () |
| putih-merah | D-SUB25 (23) = () |
| Jenis kabel | 25X0.25 [PVC] |
| coklat-biru | D-SUB25 (22) = () |
| kelabu-coklat | D-SUB25 (18) = () |
| merah jambu-coklat | D-SUB25 (20) = () |
| putih-biru | D-SUB25 (21) = () |
| putih-kelabu | D-SUB25 (17) = () |
| putih-merah jambu | D-SUB25 (19) = () |
| coklat-hijau | D-SUB25 (14) = () |
| putih-hitam | D-SUB25 (25) = () |
| putih-hijau | D-SUB25 (13) = () |
| Panjang kabel | 2 m |
| Bebas halogen | no |
| Jenis produk | System cable |
| Benang skru | UNC 4-40 |
| Gaya UL AWM | 2464/1061 |
| putih-kuning | D-SUB25 (15) = () |
| kuning-coklat | D-SUB25 (16) = () |
| Jenis konduktor | Assembled shielded round cable |
| Talian isyarat AWG | 24 |
| Semakan artikel | 02 |
| Rintangan kabel | ≤ 80 Ω/km (at 20 °C) |
| Rintangan api | IEC 60332-1-2 (raw cable) |
| Kaedah sambungan | Single wires |
| Rintangan terhadap minyak | can withstand occasional splashes (raw cable) |
| Tork pengetatan | 0.2 Nm |
| Bahan konduktor | Bare Cu litz wires |
| Semasa (Setiap laluan) | ≤ 2 A (Uncoiled, see derating) |
| Nota tentang operasi | No additional touch protection is required when using a SELV/PELV voltage (≤30 V AC or 60 V DC). |
| Bilangan jawatan | 25 |
| Tahap perlindungan | IP20 |
| Rintangan penebat | ≥ 20 MΩ*km (at 20 °C) |
| Bilangan sambungan | 1 |
| Sarung luaran, warna | gray |
| Mod operasi nominal | 100% operating factor |
| Voltan operasi (AC) | ≤ 30 V AC |
| Voltan operasi (DC) | ≤ 60 V DC |
| Sarung luar, bahan | Semi-rigid PVC |
| Keratan rentas konduktor | 25x 0.25 mm² |
| Diameter kabel luaran | 9.80 mm ±0.5 mm |
| Panjang pelucutan (Sarung) | 150 mm |
| Kitaran pemasukan/penarikan balik | > 200 |
| Diameter dawai termasuk penebat | 1.2 mm ±0.05 mm |
| Suhu ambien (operasi) | -40 °C ... 70 °C (fixed installation) |
| Talian isyarat struktur konduktor | 14x 0.15 mm |
| Kapasiti beban dinamik (lenturan) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
| Sambungan dalam akaun dengan standard | IEC 60807-2 |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 80 °C |
| Jejari lenturan terkecil, pemasangan tetap | 82 mm |
| Tahap perlindungan (Lokasi pemasangan) | ≥ IP54 (Installation location) |
| Jejari lenturan terkecil, pemasangan boleh alih | 155 mm |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi