| Parameter | Nilai |
|---|---|
| two channels | |
| Nota | The data apply for DALI bus 1 and DALI bus 2, respectively. |
| Jenis | block modular |
| Kedalaman | 54 mm |
| Lebar | 35 mm |
| Ketinggian | 126.1 mm |
| Penamaan | DALI |
| Cabutan semasa | max. 65 mA |
| Jenis produk | I/O component |
| Jenis pemasangan | DIN rail mounting |
| Arus keluaran | 230 mA (guaranteed) |
| Keluarga produk | Axioline F |
| Voltan bekalan | typ. 16 V DC (Bus voltage) |
| Nama sambungan | Axioline F connector |
| Bilangan saluran | 2 (DALI 1, DALI 2) |
| Semakan artikel | 04 |
| Tahap pencemaran | 2 (IEC 60664-1, EN 60664-1) |
| Kelas perlindungan | III (IEC 61140, EN 61140, VDE 0140-1) |
| Panjang pelucutan | 8 mm |
| Kaedah sambungan | Bus base module |
| Kedudukan pemasangan | any (no temperature derating) |
| Skop penghantaran | including bus base module and Axioline F connectors |
| Kawasan alamat input | 8 Byte |
| Nota tentang dimensi | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
| Litar pelindung | Surge protection; electronic (35 V, 0.5 s) |
| Hartanah istimewa | Single client |
| Kelajuan penghantaran | 100 Mbps |
| Jenis perlindungan | Bus protected up to 250 V AC, maximum |
| Lukisan dimensi | |
| Nota mengenai permohonan | Only for industrial use |
| Kawasan alamat output | 8 Byte |
| Tahap perlindungan | IP20 |
| Bilangan antara muka | 2 |
| Kategori voltan lampau | II (IEC 60664-1, EN 60664-1) |
| Julat voltan bekalan | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Tekanan udara (operasi) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Kapasiti bawaan semasa | max. 195 mA (Bus load, see derating) |
| Keratan rentas konduktor AWG | 24 ... 16 |
| Keratan rentas konduktor tegar | 0.2 mm² ... 1.5 mm² |
| Nota tentang kaedah sambungan | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Keratan rentas konduktor, tegar | 0.2 mm² ... 1.5 mm² |
| Suhu ambien (operasi) | -25 °C ... 60 °C |
| Voltan ujian: DALI 1 / DALI 2 | 500 V AC, 50 Hz, 1 min. |
| Tekanan udara (penyimpanan/pengangkutan) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Keratan rentas konduktor fleksibel | 0.2 mm² ... 1.5 mm² |
| Kelembapan yang dibenarkan (operasi) | 5 % ... 95 % (non-condensing) |
| Keratan rentas konduktor, fleksibel | 0.2 mm² ... 1.5 mm² |
| Arus output dengan litar pintas | max. 250 mA |
| Voltan ujian: DALI/tanah berfungsi | 1.5 kV AC, 50 Hz, 1 min. |
| Suhu ambien (penyimpanan/pengangkutan) | -40 °C ... 85 °C |
| Kelembapan yang dibenarkan (penyimpanan/pengangkutan) | 5 % ... 95 % (non-condensing) |
| Voltan ujian: Bekalan DALI/24 V (pinggir) | 1.5 kV AC, 50 Hz, 1 min. |
| Voltan ujian: Bekalan 24 V (I/O) / pembumian berfungsi | 500 V AC, 50 Hz, 1 min. |
| Voltan ujian: Bekalan DALI / 5 V bas tempatan (UBus) | 1.5 kV AC, 50 Hz, 1 min. |
| Voltan ujian: Bekalan 5 V bas tempatan (UBus) / pembumian berfungsi | 500 V AC, 50 Hz, 1 min. |
| Voltan ujian: Bekalan 5 V bas tempatan (UBus) / Bekalan 24 V (I/O) | 500 V AC, 50 Hz, 1 min. |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi