| Parameter | Nilai |
|---|---|
| GTIN | 4046356763608 |
| Kunci Pesanan | 2701508 |
| (Bekalan) | max. 2 A (at UA(IO-Link B ports, pin 2 and pin 5)) |
| Halaman katalog | Page 203 (C-6-2017) |
| Kedalaman (Nota) | 38 mm |
| Unit pembungkusan | 1 pc |
| Lebar (Nota) | 60 mm |
| Ketinggian (Nota) | 185 mm |
| (Input IO-Link) | Short-circuit protection |
| Negara asal | DE (Germany) |
| (Output digital) | 24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min. |
| Nombor tarif tersuai | 85176200 |
| Jawatan (Umum) | PROFIBUS DP |
| (Pengasingan elektrik) | Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g |
| Penamaan (Antara Muka) | PROFIBUS DP |
| Jarak lubang gerudi (Nota) | 198.5 mm |
| Bilangan saluran (Umum) | 2 |
| Nota tentang dimensi (Nota) | The height is 194.5 mm including the mounting plate. With fixing clips pulled out, the height is 212 mm. The depth is 38 mm including the mounting plate (30.5 mm without the mounting plate). |
| Lukisan dimensi (Nota) | |
| Jenis port (Input digital) | Class A |
| Kaedah sambungan (Umum) | M12 fast connection technology |
| Jenis peralatan (Antara Muka) | PROFIBUS slave |
| Jenis perlindungan (Bekalan) | Overload protection |
| (Piawaian dan Peraturan) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Kelajuan penghantaran (Umum) | 9.6 kbps ... 12 Mbps (Automatic baud rate detection) |
| Bilangan jawatan (Umum) | 5 |
| Kelewatan isyarat (input IO-Link) | max. 150 µs (when switched on) |
| (Bekalan port IO-Link) | Short-circuit protection for the sensor supply |
| Bahagian ujian (Output digital) | 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection 500 V AC 50 Hz 1 min. |
| Fizik penghantaran (Umum) | PROFIBUS-DP-compliant copper cable |
| Berat bersih (Keadaan ambien) | 710 g |
| Kadar pensuisan (input IO-Link) | 1 per second, maximum (at nominal inductive load) |
| Bilangan port (Input digital) | 4 |
| Tugasan kawasan alamat (Umum) | 1 ... 126, adjustable |
| Tahap perlindungan (Dimensi) | IP65/IP67 |
| Panjang kabel yang dibenarkan (Bekalan) | < 20 m |
| Kaedah sambungan (Input digital) | M12 fast connection technology |
| Kaedah sambungan (input IO-Link) | M12 connector, X01 ... X04 have double occupancy |
| Jenis pemasangan (Keadaan ambien) | Wall mounting or DIN rail mounting; both with mounting plate. |
| Bilangan output (input IO-Link) | max. 8 |
| Huraian output (input IO-Link) | IO-Link ports in digital output (DO) mode |
| Jenis perlindungan (input IO-Link) | Overload protection |
| Beban nominal, ohmik (input IO-Link) | 3.6 W (160 Ω, at nominal load) |
| Berat setiap Keping (tidak termasuk pembungkusan) | 710.000 g |
| Tekanan udara (operasi) (Dimensi) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Bahan perumahan (Keadaan ambien) | Zinc die-cast |
| RoHS (Piawaian dan Peraturan) China | Environmentally Friendly Use Period = 25; |
| Teknologi sambungan (Input digital) | 3-wire |
| Teknologi sambungan (input IO-Link) | 3-wire |
| Titik sambungan penetapan (Umum) | Copper cable |
| Protokol khusus sistem (Antara Muka) | PROFIBUS protocols DP V1 |
| Tingkah laku dengan beban lampau (input IO-Link) | Shutdown with automatic restart |
| Ujian mekanikal (Pengasingan elektrik) | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
| Voltan keluaran nominal (input IO-Link) | 24 V DC |
| Voltan nominal untuk bekalan I/O (Bekalan) | 24 V DC |
| Nota tentang kaedah sambungan (Umum) | B-coded |
| Kelas perlindungan (Pengasingan elektrik) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Nama input (Bekalan port IO-Link) | Digital inputs at pin 2 for type A ports |
| Beban nominal, induktif (input IO-Link) | 3.6 VA (0.8 H, 160 Ω, at nominal load) |
| Suhu ambien (operasi) (Dimensi) | -25 °C ... 60 °C |
| Tekanan udara (penyimpanan/pengangkutan) (Dimensi) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Frekuensi input (Bekalan port IO-Link) | 0.5 kHz |
| Kelembapan yang dibenarkan (operasi) (Dimensi) | 5 % ... 95 % |
| Sekatan penggunaan (Data Komersial Utama) | 1 |
| Penetapan (Had sistem pengganding bas) | Actuators (UA) |
| Bilangan input (Bekalan port IO-Link) | max. 8 (EN 61131-2 type 1) |
| Kaedah sambungan (Bekalan port IO-Link) | M12 connector, X01 ... X04 have double occupancy |
| Masa penapis input (Bekalan port IO-Link) | < 1000 µs |
| Arus nominal untuk setiap port IO-Link (Bekalan) | max. 150 mA (at C/Q (pin 4), maximum of 1.6 A over all 8 IO-Link C/Q and L+ cables) |
| Jenis perlindungan (Bekalan port IO-Link) | Overload protection |
| Arus output apabila dimatikan (input IO-Link) | max. 300 µA |
| Voltan output apabila dimatikan (input IO-Link) | max. 1 V |
| Voltan bekalan (Had sistem pengganding bas) | 24 V DC |
| Arus output maksimum setiap peranti (input IO-Link) | 1.2 A |
| Jumlah arus sensor (Bekalan port IO-Link) | max. 1.6 A (from L+/L-) |
| Teknologi sambungan (Bekalan port IO-Link) | 3-wire |
| Arus output maksimum setiap saluran (input IO-Link) | 150 mA |
| Arus input nominal (Bekalan port IO-Link) | typ. 3 mA |
| Suhu ambien (penyimpanan/pengangkutan) (Dimensi) | -25 °C ... 85 °C |
| Kaedah sambungan (Had sistem pengganding bas) | M12 connector (T-coded) |
| Kelembapan yang dibenarkan (penyimpanan/pengangkutan) (Dimensi) | 5 % ... 95 % |
| Penggunaan semasa (Had sistem pengganding bas) | typ. 30 mA ±15 % (at 24 V DC) |
| Penerangan input (Bekalan port IO-Link) | IO-Link ports in digital input (DI) mode |
| Bilangan kedudukan (Had sistem pengganding bas) | 4 |
| Voltan input nominal UIN (Bekalan port IO-Link) | 24 V DC |
| Arus sensor setiap saluran (Bekalan port IO-Link) | max. 200 mA (from L+/L-) |
| Arus input nominal pada UIN (Bekalan port IO-Link) | typ. 3 mA |
| Isyarat julat voltan input "0" (Bekalan port IO-Link) | -0.3 V DC ... 5 V DC |
| Isyarat julat voltan input "1" (Bekalan port IO-Link) | 15 V DC ... 30 V DC |
| Julat voltan bekalan nominal (Had sistem pengganding bas) | 18 V DC ... 31.2 V DC (including all tolerances, including ripple) |
| Had voltan yang disebabkan oleh gangguan litar (input IO-Link) | -15 V DC |
Spesifikasi teknikal dan data prestasi