| Parameter | Nilai |
|---|---|
| VersionClassificationeClass1227-20-05-03eClass1427-20-05-03eClass627-20-05-03eClass7.127-20-05-03eClass827-20-05-03eClass927-20-05-03eClass9.127-20-05-03ETIM8EC002993ETIM9EC002993 | |
| EAN | Not available |
| UPC | Not available |
| ETIM | 8 |
| eKelas | 12 |
| Kod Kumpulan | R3P0 |
| Nombor SCIP | |
| Faktor Logam | None |
| Kumpulan Produk | 4717 |
| Kelas produk | C: products manufactured / produced to order, which cannot be reused or re-utilised or be returned against credit. |
| Unit Kuantiti | 1 Piece |
| Kod Komoditi | 90318020 |
| Keluarga produk | Pointek CLS300 - Digital |
| Berat Bersih (kg) | 2,000 Kg |
| Negara asal | Germany |
| LKZ_FDB/ ID Katalog | FI01-4 |
| Kuantiti Pembungkusan | 1 |
| Penerangan Produk | Pointek CLS300 RF Capacitance point level switch, digital, high temperature design. Detects level and interface in aggressive liquids, solids, slurries, and foam. Adjustable, 1 m (3.28 ft), insertion, adaptable sensitivity, with active shield to tune out build-up on probe. With display and digital communications. Process Connection: Welded flange, 316L stainless steel, raised face: 4" ASME, 300 lb Probe Length: (Lengths from flange face) Extended rod, length 1000 mm (39.37") . Wetted Seals: Graphite Probe Material: 316L Stainless Steel with Ceramic Isolators Approvals: Dust Ignition Proof CE, UKCA, RCM, ATEX, UKEX II 1/2D Ex ia/tb Enclosure and Lid: Aluminum epoxy coated 2 x M20 x 1.5 cable inlet, IP65 Active Shield Length: Extended Shield - (250 mm threaded, 230 mm flanged) |
| Kitaran Hayat Produk (PLM) | PM300:Active Product |
| Peraturan Kawalan Eksport | ECCN : EAR99 / AL : N |
| Surcaj untuk Bahan Mentah | None |
| Unit ukuran saiz pakej | Not available |
| Nombor Artikel (Nombor Berhadapan Pasaran) | 7ML5662-5PD00-0BB1 |
| Anggaran masa penghantaran (Hari Bekerja) | On request |
| Obligasi Pengambilan Balik WEEE (2012/19/EU) | Yes |
| Kumpulan Harga Khusus Wilayah / Kumpulan Harga Ibu Pejabat | 8L3 / 8L3 |
| Pematuhan dengan sekatan bahan mengikut arahan RoHS | Since: 20.07.2017 |
| REACH Perkara 33 Kewajipan untuk memaklumkan mengikut senarai calon semasa | Reach InformationThere is currently no information on SVHC (Substances of Very High Concern http://echa.europa.eu/web/guest/candidate-list-table) from the supply chain and our established procedures for screening our products for Substances of Very High Concern.We compare our products regularly with the information of the upstream users with regard to the substances indicated in the candidate list in accordance with the requirements of the REACH regulation. As soon as we have new findings, our information will be updated accordingly. |
Spesifikasi teknikal dan data prestasi
Panduan pemasangan dan operasi